Cat EGP Switchgear

Back to

EGP (Emergency Generator Paralleling) switchgear is used for paralleling multiple generators that are not directly connected to a utility source.

Pricing: Contact for Pricing

Request a New Equipment Quote

Fill out this form below and we will get back to you within 1 to 2 business days! Alternatively, give us a call at 833-286-3561


    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Request a Quote Request Demo
    Application LV and MV (208V - 38 kV)
    Configuration Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications
    Modes of Operation Multi-unit Island and multi-unit standby mode with optional redundant controls and components.
    ANSI Protective Devices 15/25, 27/59, 81 O/U, 32, 40, 50, 51
    Certifications IBC, CBC, UBC & OSHPD Certified
    Control Panel Enclosure NEMA 1 or NEMA 3R Freestanding Construction
    Low Voltage Standards NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70
    Medium Voltage Standards NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110
    Operating Temperature 0°C to 50°C
    Storage Temperature -20°C to +60°C

    Standard Equipment:

    • Choice of 19” Surface Acoustic Wave Color or 15” Resistive Color Touchscreen
    • Emergency Stop Button for each generator
    • Instant Auto Switch
    • Generator Demand Priority Control
    • Audible Alarm & Horn Silence Button
    • Circuit Breaker Control Switch with Indicators

    Optional Equipment:

    • * Accomodates interface with a building management system for monitoring all system parameters via Modbus RTU or TCP
    • * Provides additional discrete synchronization protection
    • * To monitor breaker status, alarms, metering and other operating parameters

    What Our Customers Are Saying About Us

    3.9
    Based on 46 reviews
    powered by Google
    Renee Herndon
    21:55 29 Feb 24
    Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
    David Lawrence
    13:04 22 Feb 24
    Brandon Pierce
    22:00 18 Feb 24
    Darin Noe
    01:17 16 Feb 24
    Jose Soto
    15:26 23 Sep 23
    Hunter Elliott
    16:17 07 Sep 23
    Rick Kelly-Crapse
    21:06 25 Aug 23
    They had all my parts for my 3208 Cat.Friendly folks at parts counter.
    js_loader