Cat® CG – ATS for general purpose applications

Back to

The CG Series – Contactor-type, Open Transition (CG) and Delayed Transition (CGD) ATS for general purpose applications offers functionality for critical emergency power applications in commercial and light industrial applications, with an enhanced feature set and LCD HMI interface.

The CG provides a durable mechanism that is tested up to 6,000 cycles. Electrical system parameters are set via the HMI and pre-configuration file upload is available via USB or Bluetooth connection.

Pricing: Contact for Pricing

Request a quote
Rating Range 30 - 3000 A
Switch Type Contactor
Transfer Type Open Transition (CG), Delayed Transition (CGD)
Neutral configuration Optional Solid or Switched neutral
Number of poles 2, 3 and 4 (3 & 4 pole only >600A)
Phase system Single and Three (three phase only >600A)
Product nodes 30, 60, 100, 125, 160, 200, 260, 400, 600, 800, 1000, 1200, 1600, 2000, 2600, 3000A
Product type Open transition (I-II), Delayed Transition (I-O-II)
Rated Voltage and Frequency 200-480VAC, 50/60 Hz

Standard Equipment:

  • Control
    • LCD + keys
    • Voltage and frequency settings: Pick up and Drop out
    • Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF, Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead
    • Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
  • Additional Features
    • LED indications for ATS, S1 and S2 status
    • Open transition - Standard digital inputs/outputs (1/1)
    • Delayed transition - Standard digital inputs/outputs (2/1)
    • Programmable digital inputs/outputs
    • Auto config (voltage, frequency, phase system)
    • Source priority (Source 1/2, No priority)
    • Manual re-transfer
    • In-phase monitor (synchro check)
    • Genset exercising: on-load, off-load
    • Load shedding
    • Real time clock
    • Event log

Optional Equipment:

  • Accessories
    • Auxiliary contacts for position indication
    • Additional digital input/output contacts (adding up to 6 each)
    • 12-24 VDC aux supply module for controller
    • Communication modules
  • Connectivity Capability
    • Modbus RTU (RS-485)
    • Modbus/TCP
    • Profibus DP
    • ProfiNet Yes
    • DeviceNet
    • Ethernet IP

Coming Soon

What Our Customers Are Saying About Us

Renee HerndonRenee Herndon
21:55 29 Feb 24
Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
David LawrenceDavid Lawrence
13:04 22 Feb 24
Brandon PierceBrandon Pierce
22:00 18 Feb 24
Darin NoeDarin Noe
01:17 16 Feb 24
Jose SotoJose Soto
15:26 23 Sep 23
Hunter ElliottHunter Elliott
16:17 07 Sep 23
Rick Kelly-CrapseRick Kelly-Crapse
21:06 25 Aug 23
They had all my parts for my 3208 Cat.Friendly folks at parts counter.
js_loader