Cat® CG – ATS for general purpose applications

Back to

The CG Series – Contactor-type, Open Transition (CG) and Delayed Transition (CGD) ATS for general purpose applications offers functionality for critical emergency power applications in commercial and light industrial applications, with an enhanced feature set and LCD HMI interface.

The CG provides a durable mechanism that is tested up to 6,000 cycles. Electrical system parameters are set via the HMI and pre-configuration file upload is available via USB or Bluetooth connection.

Pricing: Contact for Pricing

Request a New Equipment Quote

Fill out this form below and we will get back to you within 1 to 2 business days! Alternatively, give us a call at 833-286-3561


    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Request a Quote Request Demo
    Rating Range 30 - 3000 A
    Switch Type Contactor
    Transfer Type Open Transition (CG), Delayed Transition (CGD)
    Neutral configuration Optional Solid or Switched neutral
    Number of poles 2, 3 and 4 (3 & 4 pole only >600A)
    Phase system Single and Three (three phase only >600A)
    Product nodes 30, 60, 100, 125, 160, 200, 260, 400, 600, 800, 1000, 1200, 1600, 2000, 2600, 3000A
    Product type Open transition (I-II), Delayed Transition (I-O-II)
    Rated Voltage and Frequency 200-480VAC, 50/60 Hz

    Standard Equipment:

    • LCD + keys
    • Voltage and frequency settings: Pick up and Drop out
    • Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF, Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead
    • Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
    • LED indications for ATS, S1 and S2 status
    • Open transition - Standard digital inputs/outputs (1/1)
    • Delayed transition - Standard digital inputs/outputs (2/1)
    • Programmable digital inputs/outputs
    • Auto config (voltage, frequency, phase system)
    • Source priority (Source 1/2, No priority)
    • Manual re-transfer
    • In-phase monitor (synchro check)
    • Genset exercising: on-load, off-load
    • Load shedding
    • Real time clock
    • Event log

    Optional Equipment:

    • Auxiliary contacts for position indication
    • Additional digital input/output contacts (adding up to 6 each)
    • 12-24 VDC aux supply module for controller
    • Communication modules
    • Modbus RTU (RS-485)
    • Modbus/TCP
    • Profibus DP
    • ProfiNet Yes
    • DeviceNet
    • Ethernet IP

    Coming Soon

    What Our Customers Are Saying About Us

    3.9
    Based on 46 reviews
    powered by Google
    Renee Herndon
    21:55 29 Feb 24
    Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
    David Lawrence
    13:04 22 Feb 24
    Brandon Pierce
    22:00 18 Feb 24
    Darin Noe
    01:17 16 Feb 24
    Jose Soto
    15:26 23 Sep 23
    Hunter Elliott
    16:17 07 Sep 23
    Rick Kelly-Crapse
    21:06 25 Aug 23
    They had all my parts for my 3208 Cat.Friendly folks at parts counter.
    js_loader