3516E Low Voltage Generator Set

Back to

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Pricing: Contact for Pricing

Duty Cycle Standby, Mission Critical, Prime
Emissions/Fuel Strategy Tier 2
Frequency 60 Hz
Maximum Rating 3000 ekW
Minimum Rating 2725 ekW
Prime Power Rating 2725 ekW
Speed 1800 rpm
Standby Rating 3000 ekW
Voltage 416 to 13,800 Volts
Aspiration ATAAC
Bore 6.69in
Compression Ratio 13.9:1 / 14.3:1
Displacement 4765in³
Engine Model 3516E, V-16, 4-Stroke, Water-Cooled Diesel
Fuel System MEUI
Governor Type Adem™ A5
Stroke 8.47in
Dry Weight - Genset (maximum) 44930lb
Height - Maximum 143in
Length - Maximum 304in
Width - Maximum 113in

Standard Equipment:

  • Air Inlet System
    • Single element canister type with service indicator
    • Air cleaner
  • Cooling
    • Package mounted radiator
  • Exhaust
    • Exhaust flange outlet
  • Fuel
    • Primary fuel filter with integral water separator
    • Fuel priming pump
  • Generator
    • IP23 Protection
    • Matched to the performance and output characteristics of Cat engines
  • Power Termination
    • Busbar
  • Starting/charging
    • Heavy duty starting system
    • Charging alternator
  • Control Panel
    • Over/under voltage (27/59)
    • Emergency stop pushbutton
    • Speed adjust
    • Accessory module data link
    • Generator phase sequence
    • Panel lights
    • Alarm acknowledge
    • Generator mounted - rear facing
    • kW (per phase, average & percent)
    • Engine cool-down timer
    • Communications:
    • High coolant temperature
    • Warning/shutdown with common LED indication of shutdowns for:
    • Overcurrent (50/51)
    • Amps (per phase & average)
    • Oil pressure (psi, kPa or bar)
    • Serial annunciator module data link
    • 24 Volt DC operation
    • Cat ECS controller includes:
    • DC volts
    • Reverse reactive power (kVAr) (32RV)
    • 6 Programmable digital inputs
    • 2 Programmable relay outputs (Form C)
    • Frequency (Hz)
    • Customer data link (Modbus RTU)
    • Power factor (per phase & average)
    • kW-hr (total)
    • Cat ECS 100
    • Lamp test
    • kVA (per phase, average & percent)
    • kVAr-hr (total)
    • Coolant temperature
    • Text alarm/event descriptions
    • Over/under frequency (81 o/u)
    • kVAr (per phase, average & percent)
    • 4 Programmable relay outputs (Form A)
    • Low coolant level
    • True RMS AC metering, 3-phase, +/-2% accuracy
    • Failure to start (overcrank)
    • Operating hours
    • Low coolant temperature
    • 2 Programmable digital outputs
    • Low oil pressure
    • Controls:
    • Digital indication for:
    • Environmental sealed front face
    • Overspeed
    • Volts (L-L & L-N)
    • Reverse power (kW) (32)
    • Engine cycle crank
    • Programmable protective relaying functions:
  • Cooling System
    • Fan and belt guards
    • JWAC
    • Radiator fan and fan drive
    • Coolant level sensors
    • Caterpillar extended life coolant
    • Coolant drain line with valve
  • Exhaust System
    • Flanged faced outlet(s)
    • Dry exhaust manifold
  • Fuel System
    • Fuel cooler; not included with packages without radiator
    • Fuel priming pump
    • Secondary fuel filters
    • Flexible fuel lines - shipped loose
  • Generators And Attachments
    • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
    • NEMA standard hole pattern
    • Anti-condensation space heater
    • Permanent magnet excitation (PMG)
    • Form wound
    • 3 Phase brushless, Salient pole
    • 6 Lead
    • Winding temperature detectors
    • Right side extension terminal box, busbar connections, top mounted, bottom cable entry
  • Governing System
    • ADEM III
  • Literature
    • Parts book
  • Lube System
    • Gear type lube oil pump
    • Integral lube Oil cooler
    • Fumes disposal
    • Oil drain lines and valve
    • Oil filter, filler and dipstick
    • Lubricating oil
  • Mounting System
    • Rubber anti-vibration mounts - shipped loose
    • Rails - engine/generator/radiator mounting
  • Starting / Charging System
    • 45 Amp Charging alternator
    • Battery and battery rack w/cables
    • Battery disconnect switch
    • 24 Volt electric starting motor
  • General
    • Right hand servicing
    • Paint - Caterpillar yellow with high gloss black rails & radiator
    • SAE standard rotation
    • Flywheel and flywheel housing-SAE No. 00

Optional Equipment:

  • Air Inlet System
    • Air inlet protection
    • Remote air inlet adapters
    • Heavy duty air cleaners
    • Dual element air cleaners
  • Circuit Breakers
    • 2000, 2500, 3200, 4000 Amp, 4 Pole, IEC rated Circuit breakers
    • Circuit breaker harnesses
    • Masterpact breaker connections
    • P Frame breaker connections
    • 2000, 2500, 3200, 4000, 5000 Amp, 3 Pole, IEC rated Circuit breakers
    • Busbar connections
    • R Frame breaker connections
    • Cable entry options
    • 1600, 2000, 2500, 3000, 4000, 5000 Amp, 3 Pole, UL-100% rated Circuit breakers
    • Optional busbar power connections
  • Power Termination
    • Circuit breakers, IEC compliant
  • Control Panel
    • Voltage raise/lower switch
    • PC monitoring (Remote and local)
    • Generator temperature monitoring
    • Remote speed adjust
    • Annunciator modules
    • EMCP 4.4
    • Vandal proof panel door
    • Auxiliary box
    • Customer interface options
    • Ground
    • Language options
    • Load share module options
    • Mounting group - External box clips
  • Cooling System
    • Optional Serpentine radiators
    • Optional ATAAC radiators
    • Water level switch gauges
    • Expansion tanks
  • Exhaust System
    • Flexible fittings
    • Y Adapters
    • Elbows
    • Mufflers
    • Flanges
    • Flanges and exhaust fittings
  • Fuel System
    • Duplex fuel filters
    • Primary fuel filters
  • Generators And Attachments
    • Differential current transformers - 8.7 and 15 kV class
    • Alternator air cleaners
  • Instrumentation
    • Pyrometer and thermocouples
  • Lube System
    • Manual prelube pump
    • Electric prelube pumps
    • Oil level regulator
    • Lube oil in standard sump
  • Mounting System
    • Spring type vibration isolators
    • IBC Seismic vibration isolators NORAD
    • Puck style low efficiency lsolators
  • Power Connections
    • Neutral ground connections
    • 2700 & 3000 Frame
    • Grounding groups
  • Special Tests / Reports
    • Fuel consumption test
    • Torsional vibration analysis
    • Standard engine test charge
    • IBC Certifications
    • Generator set consumption test
    • Generator set test report
    • PGS Test report @ 1.0 power factor
    • PGS Test report @ 0.8 power factor
  • Starting / Charging System
    • Engine barring group
    • 10, 20, 35 and 50 Amp Battery chargers
    • Starter cover
    • Jacket water heaters
    • 24 Volt battery set - Dry
    • Electric starting motors
    • Air starting motors
    • Air pressure regulator
  • General
    • US aid emblem
    • Special paint colors

What Our Customers Are Saying About Us

Renee HerndonRenee Herndon
21:55 29 Feb 24
Dalton was very helpful, The road construction, however, was not! 😂I would rather have to sand paper an alligators @$$ in a phone booth that to get in that mess again.
David LawrenceDavid Lawrence
13:04 22 Feb 24
Brandon PierceBrandon Pierce
22:00 18 Feb 24
Darin NoeDarin Noe
01:17 16 Feb 24
Jose SotoJose Soto
15:26 23 Sep 23
Hunter ElliottHunter Elliott
16:17 07 Sep 23
Rick Kelly-CrapseRick Kelly-Crapse
21:06 25 Aug 23
They had all my parts for my 3208 Cat.Friendly folks at parts counter.
js_loader