Cat® CS – ATS (Spec Grade)

Volver

The CS Series – Contactor-type, Open Transition (CS), Delayed Transition (CSD), Closed Transition (CSCT) ATS is equipped with an intuitive full-color touchscreen HMI and is compatible with Ekip Connect software for commissioning and operation.

The CS Series has an array of standard programmable functions and is built for high performance and service with proactive outage mitigation that monitors temperature and contact health.

Precios: Contacto para precios

Solicitar un presupuesto
Rango de clasificación 30 - 3000 A
Tipo de interruptor Contactor
Tipo de transferencia Open Transition (CS), Delayed Transition (CSD), Closed Transition (CSCT)
Neutral configuration Solid neutral, Switched neutral, (Optional) Overlapping neutral
Number of poles 2, 3 and 4
Phase system Single and Three
Product nodes UL: 30-200 A, 260-1200 A, 1600-3000 A
Product type Open transition (I-II), Delayed Transition (I-O-II), Closed transition (I-O-II) 1600-3000A only
Rated Voltage and Frequency 200-480VAC, 50/60 Hz

Equipo estándar:

  • Control
    • Color touchscreen
    • Voltage and frequency settings: Pick up and Drop out
    • Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
    • Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
  • Características adicionales
    • LED indications for ATS, S1 and S2 status
    • Programmable digital inputs/outputs
    • Auto config (voltage, frequency, phase system)
    • Source priority (Source 1/2, No priority)
    • Manual re-transfer
    • In-phase monitor (synchro check)
    • Genset exercising: on-load, off-load
    • In-built power meter module
    • Load shedding
    • Real time clock
    • Event log
    • Predictive maintenance
    • Voltage and current harmonics measuring
  • Accessories
    • Auxiliary contacts for position indication
    • Digital input/output modules (factory programmed)
    • 12-24 VDC aux supply module for controller
    • Communication modules
  • Connectivity Capability
    • Modbus RTU (RS-485)
    • Modbus/TCP
    • Profibus DP
    • ProfiNet Yes
    • DeviceNet
    • Ethernet IP
  • Aplicaciones
    • Utility - Utility
    • Utility - Generator
  • Ul Short Circuit Withstand Ratings
    • Coordinated breaker WCR
    • Time-based WCR
    • Short-time ratings

Equipo opcional:

  • Optional Neutral Configuration
    • Overlapping neutral

Próximamente

What Our Customers Are Saying About Us

Renee HerndonRenee Herndon
21:55 29 feb 24
¡Dalton era muy servicial, La construcción de carreteras, sin embargo, no lo era! Prefiero tener que lijar un caimán @$$ en una cabina telefónica que para entrar en ese lío de nuevo.
David LawrenceDavid Lawrence
13:04 22 feb 24
Brandon PierceBrandon Pierce
22:00 18 feb 24
Darin NoeDarin Noe
01:17 16 Feb 24
José SotoJosé Soto
15:26 23 Sep 23
👍
Hunter ElliottHunter Elliott
16:17 07 Sep 23
Rick Kelly-CrapseRick Kelly-Crapse
21:06 25 ago 23
Tenían todas mis piezas para mi 3208 Cat.Friendly gente en el mostrador de piezas.
js_loader