Laboratory Enclosed Lubricated Vane Systems

Volver

Our enclosed lubricated vane vacuum system decreases noise levels, allowing the vacuum system to be installed right at the point of use. Perfect when paired with our enclosed air systems, offering the lowest noise levels on the market. The lubrication from the oil in this pump results in higher efficiencies, lower operating temperatures and lower sound levels than oil-less designs. The lubricated vane design also results in the highest ultimate vacuum levels of all the vacuum technologies.

The patent-pending innovative sound enclosure reduces the vacuum pump sound intensity by 4-5 times, which allows all Powerex WhisperVAC™ systems to safely fall in within the NIOSH 8 hour exposure limit.  The reduced sound levels also allows for greater flexibility in system placement since there is less nuisance risk for patients and hospital staff.

Solicitar un presupuesto
ModeloHPSCFM @ 19" HgDepósito (gal)BTU/HrdB(A) NivelFLA @ 208V FLA @ 230VFLA @ 460VHoja de especificacionesFolleto
Sistemas dúplex
LVEVD04044.6 (2)50120V199426230.228.515.3
LVEVD05045 (2074120V216766432.228.315.2
LVEVD07547.5 (2)104120V325126644.643.322.7
Sistemas Triplex
LVEVT05055 (3)111200V3251466.147.041.221.7
LVEVT07557.5 (3)156200V4876868.165.663.732.9
Sistemas Quadplex
LVEVQ05055 (4)148200V433526761.854.128.1
LVEVQ07557.5 (4)208200V650246986.684.143.1

WHISPERVAC™ SOUND REDUCING ENCLOSURE CABINET

Powerex’s trademarked sound enclosure systems offer the lowest noise levels in the industry. Each system is packaged in a rigid steel frame with powder coated panels and lined with sound-deadening insulation. The patented innovative sound enclosure reduces the vacuum pump sound intensity by 4-5 times, which allows all Powerex WhisperVAC™ systems to safely fall in within the NIOSH 8 hour exposure limit.  The reduced sound levels also allows for greater flexibility in system placement since there is less nuisance risk for patients and hospital staff.

  • Lubricated vane vacuum pumps are enclosed within sound-reducing panels
  • Sound intensity is reduced by 4-5 times versus comparable open frame systems
  • All systems are well within NIOSH limits of 8 hour exposure
  • Helps protect the hearing of healthcare facility employees
  • Improves working environment near the medical vacuum system
  • Helps avoid disturbing patients and/or hospital employees
  • Ultimate sound reduction achieved when packaged with Powerex WhisperAir™ enclosed scroll medical air systems – the quietest source equipment in the industry!
BENEFITS
  • Lowest noise level on the market
  • Extremely reliable
  • Highest ultimate vacuum levels
  • Long vane life
  • Sin gastos de agua y alcantarillado
  • Fits through a 36” door
  • Maintenance friendly
  • Easy to remove latched panels
  • Isolator bolt elevator rail for lower pump removal

CONTROL PANEL

  • PLC Controller and 6” color HMI touchscreen displaying the operating status of the system
  • UL508A listed and labeled, NEMA 4/12 encolsure
  • Building automation gateway with BacNet® protocol
  • Email notifications for alarms and service alerts
  • Visual and audible alarms for:
    • System overload trip
    • High temperature conditions
    • Service intervals
  • Panel door includes:
    • Audible and visual alarms with an acknowledge button – HOA switch for each pump

OPTIONS & ACCESSORIES

  • Premium Warranty
  • Oxygen Assured Pumps
  • Internal Tank Lining